SEFAM DREAMSTAR AUTO CPAP WITH INTEGRATED HUMIDIFIER.

dreamstar

SEFAM DREAMSTAR AUTO CPAP WITH INTEGRATED HUMIDIFIER.

  • MODEL- DREAM STAR AUTO CPAP
  • BRAND- SEFAM
  • CATEGORY- SLEEP
  • DIMENSIONS- D x W x H:23 x 20 x 12 cm
  • WEIGHT- 1.5 kg with humidifier;1.4 kg without humidifier

PRODUCT SUMMARY.
DREAM STAR AUTO is used to treat sleep apnea and OSA. DreamStar Auto operates in CPAP and Auto-CPAP modes. In its Auto-CPAP mode, DreamStar Auto automatically adjusts the pressure as a function of the severity of the detected respiratory events (apneas, hypopneas, inspiratory flow limitations, snoring). Thanks to its capability to differentiate between obstructive and central events.

CONDITIONS USED FOR.

  • SLEEP APNEA
  • OSA
Categories: ,

Enquiry for Purchase

Enquiry for Rent

  • DREAM STAR(Auto-CPAP) are equipped with state-of-the-art technologies and algorithms to optimize user comfort and compliance: comfort mode, resistance compensation for any type of mask and tube, intelligent ramp, hands-free start (Auto-on) and Auto-off are standard.DreamStar Auto’s algorithm provides the right pressure at any time.
  • It analyzes the patient’s respiration breath by breath and detects early indicators of upper airway instability (such as inspiratory flow limitations and snoring) as well as severe respiratory events (apneas and hypopneas).
  • It only responds to obstructive events and hence avoids pressure increases in the case of central hypopneas and apneas.
  • This results in earlier adoption of the treatment and less need for intervention. DreamStar Auto save the efficacy data on leaks and usage for one year in the device’s memory, along with the real patient flow over the last 16 hours of use.
  • DreamStar Analyze is the perfect tool to view and analyze usage data and waveforms and to create detailed reports for a simple and complete assessment of the treatment efficiency. DreamStar Auto work with our OxyLink oximetry and connect to our SEFAM Connect telemonitoring platform.
  • Device pressure range : 4 cmH2O to 20 cmH2O
  • Device adjustable in increments of 0.5 cmH2O Maximum steady limiting pressure at the patient connection   port under single fault condition  : 30 cmH2OMaximum pressure that can be set: 20 cmH2O.
  • Ramp duration  : 0 to 45 minutes ± 1 minute Device adjustable in increments of 5 minutes.
  • Sound pressure level  : 26 dBA with humidifier, 30 dBA without humidifier
  • Sound pressure level  : 30 dBA with humidifier, 33 dBA without humidifier
  • Patient-side connection aperture  : Conical connector 22 mm diameter
  • Lifetime planned for the device  : 5 years (8 hours per day)
  • Air intake filter efficiency  : Optional high-efficiency filter.
  • Disposable fabric HEPA paper, which is 90% effective for particles > 3 microns.
  • High Density Foam (reusable) and is 90% effective with particles > 20 microns.                                                  Integrated Humidifier performance.
  • Humidification rate  : > 10 mg H2O/l at the maximum setting for a leak flow < 60 l/min
  • Heating time  : < 45 minutes
  • Pressure loss as a function of flow  : 0.59 cmH2O at 1 l/sec 0.73 cmH2O at 1 l/sec with swivel outlet elbow
  • Compliance of the water chamber : 14.2 ml/kPa (chamber empty) 12.2 ml/kPa (chamber full)
  • Maximum service pressure  : 20 cmH2O
  • Maximum gas temperature delivered from patient tubing  : 43°C (109.4°F)
  • Input voltage (auto-ranging)  : 100 – 240 VAC (-15%, +10%), at 50 or 60Hz
  • Maximum power consumption  : 100VA at maximum setting.*
  • Current consumed at 20cmH2O with a 4mm leak  : 130 mA eff. at 230 VAC
  • DC power supply (13 V) Voltage range allowed  : 13V (-15%, +25%).

Enquire about SEFAM DREAMSTAR AUTO CPAP WITH INTEGRATED HUMIDIFIER.

[contact-form-7 404 "Not Found"]